Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Water Res X ; 13: 100117, 2021 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-34585132

RESUMEN

Biofouling is one of the major factors causing decline in membrane performance in reverse osmosis (RO) plants, and perhaps the biggest hurdle of membrane technology. Chemical cleaning is periodically carried out at RO membrane installations aiming to restore membrane performance. Typical cleaning agents used in the water treatment industry include sodium hydroxide (NaOH) and hydrochloric acid (HCl) in sequence. Rapid biofilm regrowth and related membrane performance decline after conventional chemical cleaning is a routinely observed phenomenon due to the inefficient removal of biomass from membrane modules. Since extracellular polymeric substances (EPS) make up the strongest and predominant structural framework of biofilms, disintegration of the EPS matrix should be the main target for enhanced biomass removal. Previously, we demonstrated at lab-scale the use of concentrated urea as a chemical cleaning agent for RO membrane systems. The protein denaturation property of urea was exploited to solubilize the proteinaceous foulants, weakening the EPS layer, resulting in enhanced biomass solubilization and removal from RO membrane systems. In this work, we investigated the impact of repeated chemical cleaning cycles with urea/HCl as well as NaOH/HCl on biomass removal and the potential adaptation of the biofilm microbial community. Chemical cleaning with urea/HCl was consistently more effective than NaOH/HCl cleaning over 6 cleaning and regrowth cycles. At the end of the 6 cleaning cycles, the percent reduction was 35% and 41% in feed channel pressure drop, 50% and 70% in total organic carbon, 30% and 40% in EPS proteins, and 40% and 66% in the peak intensities of protein-like matter, after NaOH/HCl cleaning and Urea/HCl cleaning, respectively. 16S ribosomal RNA (rRNA) gene sequencing of the biofilm microbial community revealed that urea cleaning does not select for key biofouling families such as Sphingomonadaceae and Xanthomonadaceae that are known to survive conventional chemical cleaning and produce adhesive EPS. This study reaffirmed that urea possesses all the desirable properties of a chemical cleaning agent, i.e., it dissolves the existing fouling layer, delays fresh fouling accumulation by inhibiting the production of a more viscous EPS, does not cause damage to the membranes, is chemically stable, and environmentally friendly as it can be recycled for cleaning.

2.
Water Res ; 197: 117047, 2021 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-33799081

RESUMEN

Efficient control of pathogenic bacteria, specifically Legionella pneumophila, is one of the main concerns when operating industrial cooling towers. Common practices to limit proliferation involves use of disinfectants, leading to formation of disinfection by-product and increase in water corrosiveness. A disinfectant-free Legionella control method would make the industry more environmentally friendly. A pilot-scale cooling tower (1 m3/h) operated with demineralized water was used to investigate the potential of high-pH conditioning as a disinfectant-free alternative for control of L. pneumophila and other pathogens. One control experiment was performed under standard full-scale operation involving sodium hypochlorite dosage. Thereafter 3 alkaline pHs of the cooling water were tested: 9.0, 9.4 and 9.6. The tests lasted between 25 and 35 days. The cooling water from the basins were analysed for total cell count by flow cytometry, L. pneumophila concentration by plate count and occasional qPCR analyses targeting the mip-gene, bacterial and eukaryotic community analyses with 16S and 18S rRNA gene amplicon sequencing, relative abundance of eukaryotic to prokaryotic DNA by qPCR of the 16S and 18S rRNA gene. The L. pneumophila analyses showed considerable growth at pH 9.0 and pH 9.4 but was maintained below detection limit (< 100 CFU/L) at pH 9.6 without disinfection. Interestingly, the results correlated with the overall abundance of protozoa in the water samples but not directly with the relative abundance of specific reported protozoan hosts of Legionella. The pathogenicity based on 16S rRNA gene amplicon sequencing of the cooling water DNA decreased with increasing pH with a strong decline between pH 9.0 and pH 9.4, from 7.1% to 1.6% of relative abundance of pathogenic genera respectively. A strong shift in microbiome was observed between each tested pH and reproducibility of the experiment at pH 9.6 was confirmed with a duplicate test lasting 80 days. High-pH conditioning ≥ 9.6 is therefore considered as an efficient disinfectant-free cooling tower operation for control of pathogenicity, including L. pneumophila.


Asunto(s)
Legionella pneumophila , Legionella , Legionella/genética , Legionella pneumophila/genética , ARN Ribosómico 16S/genética , Reproducibilidad de los Resultados , Microbiología del Agua
3.
Water Res ; 172: 115505, 2020 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-31986397

RESUMEN

Understanding the bacterial dynamics in cooling towers is imperative for the assessment of disinfection efficiency and management of microbial risks linked to aerosol formation. The objective of this study was to evaluate the impact of feed water on the cooling water bacterial microbiome and investigate the survival ability of its members when exposed to continuous chlorine disinfection. Water from an industrial cooling water system (2600 m3/h) was collected over a 5-month period at 3 locations along the feed water line and 3 locations in the cooling tower. ATP measurements suggested that the average ATP-per-cell in the cooling tower evolved independently from the average ATP-per-cell in the feed water. Flow cytometry and 16S rRNA gene amplicon sequencing were then combined to quantify the bacterial dynamics in the whole system. A mass balance based equation was established to determine net growth and net decay of the cooling tower bacterial communities in order to evaluate the impact of continuous chlorination (0.35-0.41 mg Cl2/L residual chlorine). The results indicated that cooling tower main community members were determined by the input feed water microbiome and the bacterial community structure was further shaped by varying decay rates of the microorganisms. Notably, the order Obscuribacterales showed to be growing in the cooling tower in the presence of residual chlorine up to 0.4 mg Cl2/L, with a recurrent net growth of 260 ± 95%, taking into account the impact of the concentration factor. This conclusion was only possible thanks to the systematic analysis described in this paper and generates discussion about the resistance of Obscuribacterales to residual chlorine. The described mass balance approach provides a high level of understanding on bacterial dynamics and should be considered for future characterization studies of cooling towers in which accurate investigation of microbiome changes is essential.


Asunto(s)
Desinfección , Agua , Bacterias , Cloro , ARN Ribosómico 16S , Microbiología del Agua
4.
Water Res ; 150: 1-11, 2019 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-30508707

RESUMEN

Biofouling severely impacts operational performance of membrane systems increasing the cost of water production. Understanding the effect of critical parameters of feed water such as biodegradable substrate concentration on the developed biofilm characteristics enables development of more effective biofouling control strategies. In this study, the effect of substrate concentration on the biofilm characteristics was examined using membrane fouling simulators (MFSs). A feed channel pressure drop (PD) increase of 200 mbar was used as a benchmark to study the developed biofilm. The amount and characteristics of the formed biofilm were analysed in relation to membrane performance indicators: feed channel pressure drop and permeate flux. The effect of the characteristics of the biofilm developed at three substrate concentrations on the removal efficiency of the different biofilms was evaluated applying acid/base cleaning. Results showed that a higher feed water substrate concentration caused a higher biomass amount, a faster PD increase, but a lower permeate flux decline. The permeate flux decline was affected by the spatial location and the physical characteristics of the biofilm rather than the total amount of biofilm. The slower growing biofilm developed at the lowest substrate concentration was harder to remove by NaOH/HCl cleanings than the biofilm developed at the higher substrate concentrations. Effective biofilm removal is essential to prevent a fast biofilm regrowth after cleaning. While substrate limitation is a generally accepted biofouling control strategy delaying biofouling, development of advanced cleaning methods to remove biofilms formed under substrate limited conditions is of paramount importance.


Asunto(s)
Incrustaciones Biológicas , Purificación del Agua , Biopelículas , Membranas Artificiales , Ósmosis , Agua
5.
Water Res X ; 1: 100004, 2018 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-31194008

RESUMEN

Chemical cleaning is routinely performed in reverse osmosis (RO) plants for the regeneration of RO membranes that suffer from biofouling problems. The potential of urea as a chaotropic agent to enhance the solubilization of biofilm proteins has been reported briefly in the literature. In this paper the efficiency of urea cleaning for RO membrane systems has been compared to conventionally applied acid/alkali treatment. Preliminary assessment confirmed that urea did not damage the RO polyamide membranes and that the membrane cleaning efficiency increased with increasing concentrations of urea and temperature. Accelerated biofilm formation was carried out in membrane fouling simulators which were subsequently cleaned with (i) 0.01M sodium hydroxide (NaOH) and 0.1M hydrochloric acid (HCl) (typically applied in industry), (ii) urea (CO(NH2)2) and hydrochloric acid, or (iii) urea only (1340 g/Lwater). The pressure drop over the flow channel was used to evaluate the efficiency of the applied chemical cleanings. Biomass removal was evaluated by measuring chemical oxygen demand (COD), adenosine triphosphate (ATP), protein, and carbohydrate content from the membrane and spacer surfaces after cleaning. In addition to protein and carbohydrate quantification of the extracellular polymeric substances (EPS), fluorescence excitation-emission matrix (FEEM) spectroscopy was used to distinguish the difference in organic matter of the remaining biomass to assess biofilm solubilization efficacy of the different cleaning agents. Results indicated that two-stage CO(NH2)2/HCl cleaning was as effective as cleaning with NaOH/HCl in terms of restoring the feed channel pressure drop (>70% pressure drop decrease). One-stage cleaning with urea only was not as effective indicating the importance of the second-stage low pH acid cleaning in weakening the biofilm matrix. All three chemical cleaning protocols were equally effective in reducing the concentration of predominant EPS components protein and carbohydrate (>50% reduction in concentrations). However, urea-based cleaning strategies were more effective in solubilizing protein-like matter and tyrosine-containing proteins. Furthermore, ATP measurements showed that biomass inactivation was up to two-fold greater after treatment with urea-based chemical cleanings compared to the conventional acid/alkali treatment. The applicability of urea as an alternative, economical, eco-friendly and effective chemical cleaning agent for the control of biological fouling was successfully demonstrated.

6.
Water Res ; 119: 304-311, 2017 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-28501608

RESUMEN

The porosity of spacer-filled feed channels influences the hydrodynamics of spiral-wound membrane systems and impacts the overall performance of the system. Therefore, an exact measurement and a detailed understanding of the impact of the feed channel porosity is required to understand and improve the hydrodynamics of spiral-wound membrane systems applied for desalination and wastewater reuse. The objectives of this study were to assess the accuracy of porosity measurement techniques for feed spacers differing in geometry and thickness and the consequences of using an inaccurate method on hydrodynamic predictions, which may affect permeate production. Six techniques were applied to measure the porosity namely, three volumetric techniques based on spacer strand count together with a cuboidal (SC), cylindrical (VCC) and ellipsoidal volume calculation (VCE) and three independent techniques based on volume displacement (VD), weight and density (WD) and computed tomography (CT) scanning. The CT method was introduced as an alternative for the other five already existing and applied methods in practice. Six feed spacers used for the porosity measurement differed in filament thickness, angle between the filaments and mesh-size. The results of the studies showed differences between the porosities, measured by the six methods. The results of the microscopic techniques SC, VCC and VCE deviated significantly from measurements by VD, WD and CT, which showed similar porosity values for all spacer types. Depending on the maximum deviation of the porosity measurement techniques from -6% to +6%, (i) the linear velocity deviations were -5.6% and +6.4% respectively and (ii) the pressure drop deviations were -31% and +43% respectively, illustrating the importance of an accurate porosity measurement. Because of the accuracy and standard deviation, the VD and WD method should be applied for the porosity determination of spacer-filled channels, while the CT method is recommended for numerical modelling purposes. The porosity has a linear relationship with the flow velocity and a superlinear effect on the pressure drop. Accurate porosity data are essential to evaluate feed spacer performance in spiral-wound membrane systems. Porosity of spacer-filled feed channels has a strong impact on membrane performance and biofouling impact.


Asunto(s)
Incrustaciones Biológicas , Membranas Artificiales , Filtración , Hidrodinámica , Porosidad , Purificación del Agua
7.
Water Res ; 113: 191-206, 2017 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-28214393

RESUMEN

Drinking water utilities and researchers continue to rely on the century-old heterotrophic plate counts (HPC) method for routine assessment of general microbiological water quality. Bacterial cell counting with flow cytometry (FCM) is one of a number of alternative methods that challenge this status quo and provide an opportunity for improved water quality monitoring. After more than a decade of application in drinking water research, FCM methodology is optimised and established for routine application, supported by a considerable amount of data from multiple full-scale studies. Bacterial cell concentrations obtained by FCM enable quantification of the entire bacterial community instead of the minute fraction of cultivable bacteria detected with HPC (typically < 1% of all bacteria). FCM measurements are reproducible with relative standard deviations below 3% and can be available within 15 min of samples arriving in the laboratory. High throughput sample processing and complete automation are feasible and FCM analysis is arguably less expensive than HPC when measuring more than 15 water samples per day, depending on the laboratory and selected staining procedure(s). Moreover, many studies have shown FCM total (TCC) and intact (ICC) cell concentrations to be reliable and robust process variables, responsive to changes in the bacterial abundance and relevant for characterising and monitoring drinking water treatment and distribution systems. The purpose of this critical review is to initiate a constructive discussion on whether FCM could replace HPC in routine water quality monitoring. We argue that FCM provides a faster, more descriptive and more representative quantification of bacterial abundance in drinking water.


Asunto(s)
Agua Potable/microbiología , Microbiología del Agua , Bacterias , Recuento de Células , Recuento de Colonia Microbiana , Citometría de Flujo , Calidad del Agua , Abastecimiento de Agua
8.
Water Res ; 110: 281-287, 2017 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-28027527

RESUMEN

Feed spacers are an essential part of spiral-wound reverse osmosis (RO) and nanofiltration (NF) membrane modules. Geometric modification of feed spacers is a potential option to reduce the impact of biofouling on the performance of membrane systems. The objective of this study was to evaluate the biofouling potential of two commercially available reference feed spacers and four modified feed spacers. The spacers were compared on hydraulic characterization and in biofouling studies with membrane fouling simulators (MFSs). The virgin feed spacer was characterized hydraulically by their resistance, measured in terms of feed channel pressure drop, performed by operating MFSs at varying feed water flow rates. Short-term (9 days) biofouling studies were carried out with nutrient dosage to the MFS feed water to accelerate the biofouling rate. Long-term (96 days) biofouling studies were done without nutrient dosage to the MFS feed water. Feed channel pressure drop was monitored and accumulation of active biomass was quantified by adenosine tri phosphate (ATP) determination. The six feed spacers were ranked on pressure drop (hydraulic characterization) and on biofouling impact (biofouling studies). Significantly different trends in hydraulic resistance and biofouling impact for the six feed spacers were observed. The same ranking for biofouling impact on the feed spacers was found for the (i) short-term biofouling study with nutrient dosage and the (ii) long-term biofouling study without nutrient dosage. The ranking for hydraulic resistance for six virgin feed spacers differed significantly from the ranking of the biofouling impact, indicating that hydraulic resistance of clean feed spacers does not predict the hydraulic resistance of biofouled feed spacers. Better geometric design of feed spacers can be a suitable approach to minimize impact of biofouling in spiral wound membrane systems.


Asunto(s)
Incrustaciones Biológicas , Membranas Artificiales , Biopelículas , Filtración , Ósmosis , Purificación del Agua
9.
PLoS One ; 11(10): e0164445, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27792739

RESUMEN

Large seasonal variations in microbial drinking water quality can occur in distribution networks, but are often not taken into account when evaluating results from short-term water sampling campaigns. Temporal dynamics in bacterial community characteristics were investigated during a two-year drinking water monitoring campaign in a full-scale distribution system operating without detectable disinfectant residual. A total of 368 water samples were collected on a biweekly basis at the water treatment plant (WTP) effluent and at one fixed location in the drinking water distribution network (NET). The samples were analysed for heterotrophic plate counts (HPC), Aeromonas plate counts, adenosine-tri-phosphate (ATP) concentrations, and flow cytometric (FCM) total and intact cell counts (TCC, ICC), water temperature, pH, conductivity, total organic carbon (TOC) and assimilable organic carbon (AOC). Multivariate analysis of the large dataset was performed to explore correlative trends between microbial and environmental parameters. The WTP effluent displayed considerable seasonal variations in TCC (from 90 × 103 cells mL-1 in winter time up to 455 × 103 cells mL-1 in summer time) and in bacterial ATP concentrations (<1-3.6 ng L-1), which were congruent with water temperature variations. These fluctuations were not detected with HPC and Aeromonas counts. The water in the network was predominantly influenced by the characteristics of the WTP effluent. The increase in ICC between the WTP effluent and the network sampling location was small (34 × 103 cells mL-1 on average) compared to seasonal fluctuations in ICC in the WTP effluent. Interestingly, the extent of bacterial growth in the NET was inversely correlated to AOC concentrations in the WTP effluent (Pearson's correlation factor r = -0.35), and positively correlated with water temperature (r = 0.49). Collecting a large dataset at high frequency over a two year period enabled the characterization of previously undocumented seasonal dynamics in the distribution network. Moreover, high-resolution FCM data enabled prediction of bacterial cell concentrations at specific water temperatures and time of year. The study highlights the need to systematically assess temporal fluctuations in parallel to spatial dynamics for individual drinking water distribution systems.


Asunto(s)
Bacterias , Agua Potable/microbiología , Abastecimiento de Agua/métodos , Aeromonas/crecimiento & desarrollo , Bacterias/crecimiento & desarrollo , Carga Bacteriana , Citometría de Flujo , Países Bajos , Estaciones del Año , Microbiología del Agua , Purificación del Agua/métodos
10.
Water Res ; 103: 149-159, 2016 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-27450353

RESUMEN

Understanding the factors that determine the spatial and temporal biofilm development is a key to formulate effective control strategies in reverse osmosis membrane systems for desalination and wastewater reuse. In this study, biofilm development was investigated at different water temperatures (10, 20, and 30 °C) inside a membrane fouling simulator (MFS) flow cell. The MFS studies were done at the same crossflow velocity with the same type of membrane and spacer materials, and the same feed water type and nutrient concentration, differing only in water temperature. Spatially resolved biofilm parameters such as oxygen decrease rate, biovolume, biofilm spatial distribution, thickness and composition were measured using in-situ imaging techniques. Pressure drop (PD) increase in time was used as a benchmark as to when to stop the experiments. Biofilm measurements were performed daily, and experiments were stopped once the average PD increased to 40 mbar/cm. The results of the biofouling study showed that with increasing feed water temperature (i) the biofilm activity developed faster, (ii) the pressure drop increased faster, while (iii) the biofilm thickness decreased. At an average pressure drop increase of 40 mbar/cm over the MFS for the different feed water temperatures, different biofilm activities, structures, and quantities were found, indicating that diagnosis of biofouling of membranes operated at different or varying (seasonal) feed water temperatures may be challenging. Membrane installations with a high temperature feed water are more susceptible to biofouling than installations fed with low temperature feed water.


Asunto(s)
Incrustaciones Biológicas , Agua , Biopelículas , Membranas Artificiales , Ósmosis , Temperatura , Purificación del Agua
11.
Water Res ; 94: 62-72, 2016 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-26925544

RESUMEN

Microbial processes inevitably play a role in membrane-based desalination plants, mainly recognized as membrane biofouling. We assessed the bacterial community structure and diversity during different treatment steps in a full-scale seawater desalination plant producing 40,000 m(3)/d of drinking water. Water samples were taken over the full treatment train consisting of chlorination, spruce media and cartridge filters, de-chlorination, first and second pass reverse osmosis (RO) membranes and final chlorine dosage for drinking water distribution. The water samples were analyzed for water quality parameters (total bacterial cell number, total organic carbon, conductivity, pH, etc.) and microbial community composition by 16S rRNA gene pyrosequencing. The planktonic microbial community was dominated by Proteobacteria (48.6%) followed by Bacteroidetes (15%), Firmicutes (9.3%) and Cyanobacteria (4.9%). During the pretreatment step, the spruce media filter did not impact the bacterial community composition dominated by Proteobacteria. In contrast, the RO and final chlorination treatment steps reduced the Proteobacterial relative abundance in the produced water where Firmicutes constituted the most dominant bacterial group. Shannon and Chao1 diversity indices showed that bacterial species richness and diversity decreased during the seawater desalination process. The two-stage RO filtration strongly reduced the water conductivity (>99%), TOC concentration (98.5%) and total bacterial cell number (>99%), albeit some bacterial DNA was found in the water after RO filtration. About 0.25% of the total bacterial operational taxonomic units (OTUs) were present in all stages of the desalination plant: the seawater, the RO permeates and the chlorinated drinking water, suggesting that these bacterial strains can survive in different environments such as high/low salt concentration and with/without residual disinfectant. These bacterial strains were not caused by contamination during water sample filtration or from DNA extraction protocols. Control measurements for sample contamination are important for clean water studies.


Asunto(s)
Agua Potable/microbiología , Proteobacteria/aislamiento & purificación , Agua de Mar/microbiología , Purificación del Agua/métodos , Cloro/química , ADN Bacteriano/aislamiento & purificación , Filtración , Membranas Artificiales , Ósmosis , ARN Ribosómico 16S/genética , Microbiología del Agua , Calidad del Agua
12.
Water Res ; 88: 225-234, 2016 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-26512800

RESUMEN

In recent years, forward osmosis (FO) hybrid membrane systems have been investigated as an alternative to conventional high-pressure membrane processes (i.e. reverse osmosis (RO)) for seawater desalination and wastewater treatment and recovery. Nevertheless, their economic advantage in comparison to conventional processes for seawater desalination and municipal wastewater treatment has not been clearly addressed. This work presents a detailed economic analysis on capital and operational expenses (CAPEX and OPEX) for: i) a hybrid forward osmosis - low-pressure reverse osmosis (FO-LPRO) process, ii) a conventional seawater reverse osmosis (SWRO) desalination process, and iii) a membrane bioreactor - reverse osmosis - advanced oxidation process (MBR-RO-AOP) for wastewater treatment and reuse. The most important variables affecting economic feasibility are obtained through a sensitivity analysis of a hybrid FO-LPRO system. The main parameters taken into account for the life cycle costs are the water quality characteristics (similar feed water and similar water produced), production capacity of 100,000 m(3) d(-1) of potable water, energy consumption, materials, maintenance, operation, RO and FO module costs, and chemicals. Compared to SWRO, the FO-LPRO systems have a 21% higher CAPEX and a 56% lower OPEX due to savings in energy consumption and fouling control. In terms of the total water cost per cubic meter of water produced, the hybrid FO-LPRO desalination system has a 16% cost reduction compared to the benchmark for desalination, mainly SWRO. Compared to the MBR-RO-AOP, the FO-LPRO systems have a 7% lower CAPEX and 9% higher OPEX, resulting in no significant cost reduction per m(3) produced by FO-LPRO. Hybrid FO-LPRO membrane systems are shown to have an economic advantage compared to current available technology for desalination, and comparable costs with a wastewater treatment and recovery system. Based on development on FO membrane modules, packing density, and water permeability, the total water cost could be further reduced.


Asunto(s)
Agua de Mar , Eliminación de Residuos Líquidos/economía , Eliminación de Residuos Líquidos/métodos , Purificación del Agua/economía , Purificación del Agua/métodos , Biocombustibles , Reactores Biológicos , Agua Potable , Membranas Artificiales , Ósmosis , Eliminación de Residuos Líquidos/instrumentación , Aguas Residuales , Purificación del Agua/instrumentación , Calidad del Agua
13.
Water Res ; 83: 10-20, 2015 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-26117369

RESUMEN

Biofouling is a serious problem in reverse osmosis/nanofiltration (RO/NF) applications, reducing membrane performance. Early detection of biofouling plays an essential role in an adequate anti-biofouling strategy. Presently, fouling of membrane filtration systems is mainly determined by measuring changes in pressure drop, which is not exclusively linked to biofouling. Non-destructive imaging of oxygen concentrations (i) is specific for biological activity of biofilms and (ii) may enable earlier detection of biofilm accumulation than pressure drop. The objective of this study was to test whether transparent luminescent planar O2 optodes, in combination with a simple imaging system, can be used for early non-destructive biofouling detection. This biofouling detection is done by mapping the two-dimensional distribution of O2 concentrations and O2 decrease rates inside a membrane fouling simulator (MFS). Results show that at an early stage, biofouling development was detected by the oxygen sensing optodes while no significant increase in pressure drop was yet observed. Additionally, optodes could detect spatial heterogeneities in biofouling distribution at a micro scale. Biofilm development started mainly at the feed spacer crossings. The spatial and quantitative information on biological activity will lead to better understanding of the biofouling processes, contributing to the development of more effective biofouling control strategies.


Asunto(s)
Fenómenos Fisiológicos Bacterianos , Biopelículas/crecimiento & desarrollo , Incrustaciones Biológicas , Oxígeno/análisis , Filtración , Oxígeno/química , Purificación del Agua
14.
J Magn Reson ; 252: 145-50, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25700116

RESUMEN

We demonstrate a method to manipulate magnetic resonance data such that the moments of the signal spatial distribution are readily accessible. Usually, magnetic resonance imaging relies on data acquired in so-called k-space which is subsequently Fourier transformed to render an image. Here, via analysis of the complex signal in the vicinity of the centre of k-space we are able to access the first three moments of the signal spatial distribution, ultimately in multiple directions. This is demonstrated for biofouling of a reverse osmosis (RO) membrane module, rendering unique information and an early warning of the onset of fouling. The analysis is particularly applicable for the use of mobile magnetic resonance spectrometers; here we demonstrate it using an Earth's magnetic field system.

15.
Water Res ; 67: 227-42, 2014 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-25282091

RESUMEN

The influence of organic nutrient load on biomass accumulation (biofouling) and pressure drop development in membrane filtration systems was investigated. Nutrient load is the product of nutrient concentration and linear flow velocity. Biofouling - excessive growth of microbial biomass in membrane systems - hampers membrane performance. The influence of biodegradable organic nutrient load on biofouling was investigated at varying (i) crossflow velocity, (ii) nutrient concentration, (iii) shear, and (iv) feed spacer thickness. Experimental studies were performed with membrane fouling simulators (MFSs) containing a reverse osmosis (RO) membrane and a 31 mil thick feed spacer, commonly applied in practice in RO and nanofiltration (NF) spiral-wound membrane modules. Numerical modeling studies were done with identical feed spacer geometry differing in thickness (28, 31 and 34 mil). Additionally, experiments were done applying a forward osmosis (FO) membrane with varying spacer thickness (28, 31 and 34 mil), addressing the permeate flux decline and biofilm development. Assessed were the development of feed channel pressure drop (MFS studies), permeate flux (FO studies) and accumulated biomass amount measured by adenosine triphosphate (ATP) and total organic carbon (TOC). Our studies showed that the organic nutrient load determined the accumulated amount of biomass. The same amount of accumulated biomass was found at constant nutrient load irrespective of linear flow velocity, shear, and/or feed spacer thickness. The impact of the same amount of accumulated biomass on feed channel pressure drop and permeate flux was influenced by membrane process design and operational conditions. Reducing the nutrient load by pretreatment slowed-down the biofilm formation. The impact of accumulated biomass on membrane performance was reduced by applying a lower crossflow velocity and/or a thicker and/or a modified geometry feed spacer. The results indicate that cleanings can be delayed but are unavoidable.


Asunto(s)
Biopelículas/crecimiento & desarrollo , Incrustaciones Biológicas , Filtración/instrumentación , Membranas Artificiales , Modelos Teóricos , Purificación del Agua/instrumentación , Biomasa , Filtración/métodos , Ósmosis , Presión , Salinidad , Purificación del Agua/métodos
16.
Water Res ; 67: 243-54, 2014 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-25282092

RESUMEN

Biofouling causes performance loss in spiral wound nanofiltration (NF) and reverse osmosis (RO) membrane operation for process and drinking water production. The development of biofilm formation, structure and detachment was studied in-situ, non-destructively with Optical Coherence Tomography (OCT) in direct relation with the hydraulic biofilm resistance and membrane performance parameters: transmembrane pressure drop (TMP) and feed-channel pressure drop (FCP). The objective was to evaluate the suitability of OCT for biofouling studies, applying a membrane biofouling test cell operated at constant crossflow velocity (0.1 m s(-1)) and permeate flux (20 L m(-2)h(-1)). In time, the biofilm thickness on the membrane increased continuously causing a decline in membrane performance. Local biofilm detachment was observed at the biofilm-membrane interface. A mature biofilm was subjected to permeate flux variation (20 to 60 to 20 L m(-2)h(-1)). An increase in permeate flux caused a decrease in biofilm thickness and an increase in biofilm resistance, indicating biofilm compaction. Restoring the original permeate flux did not completely restore the original biofilm parameters: After elevated flux operation the biofilm thickness was reduced to 75% and the hydraulic resistance increased to 116% of the original values. Therefore, after a temporarily permeate flux increase the impact of the biofilm on membrane performance was stronger. OCT imaging of the biofilm with increased permeate flux revealed that the biofilm became compacted, lost internal voids, and became more dense. Therefore, membrane performance losses were not only related to biofilm thickness but also to the internal biofilm structure, e.g. caused by changes in pressure. Optical Coherence Tomography proved to be a suitable tool for quantitative in-situ biofilm thickness and morphology studies which can be carried out non-destructively and in real-time in transparent membrane biofouling monitors.


Asunto(s)
Biopelículas/crecimiento & desarrollo , Incrustaciones Biológicas , Filtración/instrumentación , Membranas Artificiales , Nanoestructuras , Tomografía de Coherencia Óptica/métodos , Purificación del Agua/instrumentación , Filtración/métodos , Movimientos del Agua , Purificación del Agua/métodos
17.
Water Res ; 66: 122-139, 2014 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-25201336

RESUMEN

This review focuses on the present status of forward osmosis (FO) niches in two main areas: seawater desalination and wastewater reuse. Specific applications for desalination and impaired-quality water treatment and reuse are described, as well as the benefits, advantages, challenges, costs and knowledge gaps on FO hybrid systems are discussed. FO can play a role as a bridge to integrate upstream and downstream water treatment processes, to reduce the energy consumption of the entire desalination or water recovery and reuse processes, thus achieving a sustainable solution for the water-energy nexus. FO hybrid membrane systems showed to have advantages over traditional membrane process like high pressure reverse osmosis and nanofiltration for desalination and wastewater treatment: (i) chemical storage and feed water systems may be reduced for capital, operational and maintenance cost, (ii) water quality is improved, (iii) reduced process piping costs, (iv) more flexible treatment units, and (v) higher overall sustainability of the desalination and wastewater treatment process. Nevertheless, major challenges make FO systems not yet a commercially viable technology, the most critical being the development of a high flux membrane, capable of maintaining an elevated salt rejection and a reduced internal concentration polarization effect, and the availability of appropriate draw solutions (cost effective and non-toxic), which can be recirculated via an efficient recovery process. This review article highlights the features of hybrid FO systems and specifically provides the state-of-the-art applications in the water industry in a novel classification and based on the latest developments toward scaling up these systems.


Asunto(s)
Ósmosis , Eliminación de Residuos Líquidos/métodos , Purificación del Agua/métodos , Agua de Mar/análisis
18.
Water Res ; 63: 179-89, 2014 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-25000200

RESUMEN

The combination of flow cytometry (FCM) and 16S rRNA gene pyrosequencing data was investigated for the purpose of monitoring and characterizing microbial changes in drinking water distribution systems. High frequency sampling (5 min intervals for 1 h) was performed at the outlet of a treatment plant and at one location in the full-scale distribution network. In total, 52 bulk water samples were analysed with FCM, pyrosequencing and conventional methods (adenosine-triphosphate, ATP; heterotrophic plate count, HPC). FCM and pyrosequencing results individually showed that changes in the microbial community occurred in the water distribution system, which was not detected with conventional monitoring. FCM data showed an increase in the total bacterial cell concentrations (from 345 ± 15 × 10(3) to 425 ± 35 × 10(3) cells mL(-1)) and in the percentage of intact bacterial cells (from 39 ± 3.5% to 53 ± 4.4%) during water distribution. This shift was also observed in the FCM fluorescence fingerprints, which are characteristic of each water sample. A similar shift was detected in the microbial community composition as characterized with pyrosequencing, showing that FCM and genetic fingerprints are congruent. FCM and pyrosequencing data were subsequently combined for the calculation of cell concentration changes for each bacterial phylum. The results revealed an increase in cell concentrations of specific bacterial phyla (e.g., Proteobacteria), along with a decrease in other phyla (e.g., Actinobacteria), which could not be concluded from the two methods individually. The combination of FCM and pyrosequencing methods is a promising approach for future drinking water quality monitoring and for advanced studies on drinking water distribution pipeline ecology.


Asunto(s)
Dermatoglifia del ADN , Agua Potable/microbiología , Monitoreo del Ambiente/métodos , Citometría de Flujo , Calidad del Agua , ADN Bacteriano/genética , Países Bajos , ARN Ribosómico 16S/genética , Análisis de Secuencia de ADN , Abastecimiento de Agua
19.
Water Res ; 64: 160-176, 2014 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-25055226

RESUMEN

Deposition of microspheres mimicking bacterial cells was studied experimentally and with a numerical model in feed spacer membrane channels, as used in spiral wound nanofiltration (NF) and reverse osmosis (RO) membrane systems. In-situ microscopic observations in membrane fouling simulators revealed formation of specific particle deposition patterns for different diamond and ladder feed spacer orientations. A three-dimensional numerical model combining fluid flow with a Lagrangian approach for particle trajectory calculations could describe very well the in-situ observations on particle deposition in flow cells. Feed spacer geometry, positioning and cross-flow velocity sensitively influenced the particle transport and deposition patterns. The deposition patterns were not influenced by permeate production. This combined experimental-modeling approach could be used for feed spacer geometry optimization studies for reduced (bio)fouling.


Asunto(s)
Filtración/métodos , Membranas Artificiales , Incrustaciones Biológicas , Microesferas , Modelos Biológicos , Nanotecnología , Ósmosis , Movimientos del Agua
20.
Water Res ; 57: 223-33, 2014 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-24726992

RESUMEN

Forward osmosis (FO) indirect desalination systems integrate wastewater recovery with seawater desalination. Niche applications for FO systems have been reported recently, due to the demonstrated advantages compared to conventional high-pressure membrane processes such as nanofiltration (NF) and reverse osmosis (RO). Among them, wastewater recovery has been identified to be particularly suitable for practical applications. However, biofouling in FO membranes has rarely been studied in applications involving wastewater effluents. Feed spacers separating the membrane sheets in cross-flow systems play an important role in biofilm formation. The objective of this study was to determine the influence of feed spacer thickness (28, 31 and 46 mil) on biofouling development and membrane performance in a FO system, using identical cross-flow cells in parallel studies. Flux development, biomass accumulation, fouling localization and composition were determined and analyzed. For all spacer thicknesses, operated at the same feed flow and the same run time, the same amount of biomass was found, while the flux reduction decreased with thicker spacers. These observations are in good agreement with biofouling studies for RO systems, considering the key differences between FO and RO. Our findings contradict previous cross-flow studies on particulate/colloidal fouling, where higher cross-flow velocities improved system performance. Thicker spacers reduced the impact of biofouling on FO membrane flux.


Asunto(s)
Incrustaciones Biológicas , Filtración , Ósmosis , Eliminación de Residuos Líquidos/instrumentación , Purificación del Agua/instrumentación , Microscopía Confocal , Microscopía Electrónica de Rastreo , Presión Osmótica , Agua de Mar/química , Aguas Residuales/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...